170501 -99.00 -99.00 1.64 0.43 170502 -99.00 -99.00 1.64 0.20 170503 -99.00 -99.00 1.42 0.20 170504 -99.00 -99.00 1.48 0.20 170505 -99.00 -99.00 1.48 0.43 hot jump 170506 -99.00 -99.00 1.58 0.43 170507 -99.00 -99.00 1.50 0.43 Zdr jump cooler 170508 -99.00 -99.00 1.55 0.14 170509 -99.00 -99.00 1.44 0.14 170510 -99.00 -99.00 1.47 0.14 Zdr change cooler - unknown why 170511 -99.00 -99.00 1.45 0.00 Zdr this day shows no bias 170510 -99.00 -99.00 1.47 0.00 170511 -99.00 -99.00 1.45 0.00 170512 -99.00 -99.00 1.57 0.00; fluctuations -0.1 --> +0.1 170513 -99.00 -99.00 1.62 0.00; fluctuations 170514 -99.00 -99.00 1.53 0.00 170515 -99.00 -99.00 1.51 0.00 170516 -99.00 -99.00 1.51 0.00 170517 -99.00 -99.00 1.46 0.00 170518 -99.00 -99.00 1.63 0.00 170519 -99.00 -99.00 1.57 0.21; visual data inspection 170520 -99.00 -99.00 1.67 0.21; BB 170521 -99.00 -99.00 1.67 0.21; no precip ********************************** Zdr data from 170522 through 170531 not to be used for science due to fluctuations. It was discovered later that waveguide purge with N2 was needed to remove moisture. Zdr fluctuating by more than 0.4 dB. *********************************** I would suggest just applying 0.00 dB as Zdr cal adjustment unless noted for OP data only. Zdr data are not reliable. ************************************* 170522 -99.00 -99.00 1.55 0.00 170523 -99.00 -99.00 1.55 0.00; (-0.29 for OP only - otherwise 0.00) 170524 -99.00 -99.00 1.55 0.00 170525 -99.00 -99.00 1.55 0.00; (-0.09 for OP only; otherwise 0.00) 170526 -99.00 -99.00 1.54 0.00 170527 -99.00 -99.00 1.58 0.00 170528 -99.00 -99.00 1.61 0.00; (-0.23 for OP only - otherwise 0.00) 170529 -99.00 -99.00 1.58 0.00 170530 -99.00 -99.00 1.75 0.00 170531 -99.00 -99.00 1.69 0.00